Clear Path Home Inspections
reports@clearpath.example · (555) 214-7780 · License LIC-18473
Home inspection report
Jun 24, 2026
1842 Cedar Ridge Lane, Greenville, SC
Client
Megan Carter
Inspection date
Jun 24, 2026
Agent
Riley Brooks
Report status
published
42/42
Items inspected
31
Functional
7
Marginal
3
Defects
1
Safety
ASummary
4 items that deserve attention first
Roof
DefectFlashings
Repair damaged chimney flashing to prevent water intrusion.

Exterior
DefectGrading and drainage
Improve grading and downspout discharge at the rear foundation wall.

Plumbing
DefectDrain, waste, and vent
Repair the leaking kitchen sink drain trap.

Electrical
SafetyMain panel
Install listed filler plates at the open panel knockouts.

BInspection details
01Roof
4 of 4 items inspected
Functional at time of inspection
Roof penetrations
Roof
Roof covering
The architectural shingles show granule loss and general wear consistent with age, most visible on the south-facing plane. No active leakage was observed from accessible vantage points. Recommend annual monitoring and budgeting for replacement within the covering's remaining service life.
Roof
Flashings
Damaged and lifted flashing was observed where the chimney meets the roof plane. This condition is a common source of concealed water intrusion into the roof assembly. Recommend correction by a qualified roofing contractor before the next heavy rain season.


Roof
Gutters and drainage
Debris was visible in the gutters at several runs. Recommend cleaning and verifying that downspouts discharge away from the foundation as routine maintenance.
02Exterior
4 of 4 items inspected
Functional at time of inspection
Windows and doors, Decks, porches, and steps
Exterior
Siding and trim
Sealant gaps were observed at several trim joints and exterior penetrations. Recommend re-caulking as routine maintenance to limit moisture and pest entry.
Exterior
Grading and drainage
Soil slopes toward the structure along the rear foundation wall and staining was visible on the lower courses. Sustained drainage toward the foundation promotes moisture intrusion. Recommend regrading to direct water away from the structure and extending the downspout discharge.

03Foundation / Structure
3 of 3 items inspected
Functional at time of inspection
Visible framing, Crawlspace / basement
Foundation / Structure
Foundation
Minor cracks consistent with normal concrete shrinkage were observed at the foundation. No significant displacement or moisture intrusion was noted at these locations. Recommend sealing and periodic monitoring.
04Plumbing
4 of 4 items inspected
Functional at time of inspection
Water supply piping, Fixtures and faucets
Plumbing
Drain, waste, and vent
Leak staining and corrosion were observed below the kitchen sink drain trap, and the surrounding cabinet base shows prior moisture exposure. Recommend repair by a qualified plumbing contractor and verification that surrounding materials have dried.

Plumbing
Water heater
The 50-gallon water heater is operating but is at or beyond its typical service life based on the manufacture date. Recommend budgeting for replacement and monitoring for leakage at the tank base.
05Electrical
4 of 4 items inspected
Functional at time of inspection
Service equipment, Branch wiring
Electrical
Main panel
Open knockouts were observed in the main panel enclosure, exposing energized parts to contact. This is a shock and fire safety concern. Recommend installing listed filler plates; correction is inexpensive and typically quick for a qualified electrician.

Electrical
GFCI / AFCI protection
GFCI devices at the kitchen, bathrooms, and exterior receptacles tripped and reset properly when tested.
06HVAC
4 of 4 items inspected
Functional at time of inspection
Distribution and ductwork, Thermostat operation
HVAC
Heating equipment
The furnace responded to normal operating controls but shows signs that routine professional servicing is overdue. Annual servicing extends equipment life and maintains efficiency. Recommend servicing by a qualified HVAC contractor.
HVAC
Cooling equipment
The cooling system responded to normal operating controls and produced an appropriate temperature differential at the supply registers.
07Interior
4 of 4 items inspected
Functional at time of inspection
Interior doors, Interior windows, Stairs and railings
Interior
Walls, ceilings, and floors
A prior water stain was observed on the dining room ceiling; the area tested dry with a moisture meter at the time of inspection, suggesting a past event. Recommend asking the seller about repair history and monitoring the area.
08Kitchen
4 of 4 items inspected
Functional at time of inspection
Cabinets and counters, Sink and plumbing, Installed appliances, Ventilation
09Bathrooms
4 of 4 items inspected
Functional at time of inspection
Fixtures, Tub / shower, Floors and walls
Bathrooms
Ventilation
The hall bathroom exhaust fan is operative but noticeably weak. Recommend cleaning or replacing the fan to maintain adequate moisture removal.
10Attic / Insulation
4 of 4 items inspected
Functional at time of inspection
Access, Ventilation, Visible roof structure
Attic / Insulation
Insulation
Attic insulation depth appears below current energy standards in portions of the attic. Adding insulation is a cost-effective efficiency improvement. Recommend upgrading when convenient.
11Garage
3 of 3 items inspected
Functional at time of inspection
Fire separation, Garage electrical
Garage
Vehicle door and opener
The vehicle door opener responded to controls, auto-reversed under resistance, and the photo sensors operated as intended.